Health overview
Status now
| Signal | Before treatmentJan 08 to Mar 15 | Ruxolitinib + bisoprololApr 08 to Oct 10 | Off bisoprololOct 11 to Nov 24 | Last 7 nightsNov 18 to Nov 24 |
|---|---|---|---|---|
| Night HRV (RMSSD)ms | 9.0n=64 | 26.8n=164 | 16.0n=43 | 14.7n=7 |
| Sleeping heart ratebpm | 85.2n=64 | 67.8n=164 | 73.5n=43 | 73.7n=7 |
| Lowest night heart ratebpm | 76.7n=64 | 59.0n=164 | 65.1n=43 | 65.1n=7 |
| Sleeph | 5.9n=64 | 6.9n=164 | 6.2n=43 | 6.7n=7 |
| SpO2, Oura ring% | 96.1n=55 | 95.4n=132 | 94.9n=34 | 94.4n=6 |
| SpO2, Checkme oximeter% of night, sleep window | no data | 94.7n=19 | 94.2n=14 | 94.0n=1 |
Oura nights with a failed SpO2 reading (stored as 0) are left out of the SpO2 row. Bisoprolol pause nights (May 20 to May 23 and Jul 20 to Aug 03) are left out of the bisoprolol column. The before-treatment window is the same as the front page (Jan 08 to Mar 15).
Treatment timeline
Phases from the medicine dates in the project configuration: ruxolitinib Mar 16, bisoprolol Apr 08 to Oct 10 with pauses May 20 to May 23 and Jul 20 to Aug 03 (hatched). Hepatitis E was diagnosed on Mar 18, 2 days after ruxolitinib started.
Heart and circulation
24 h ECG, 4 recordings
| Recording | Beats | PVC | PVC % | VT runs | HR bpm |
|---|---|---|---|---|---|
| 2026-05-04on bisoprolol | 98,874 | 6,726 | 6.80 | 1longest 2 s | 7047 to 104 |
| 2026-05-15on bisoprolol | 98,180 | 11,223 | 11.43 | 3longest 4 s | 7048 to 120 |
| 2026-10-06on bisoprolol | 111,204 | 5 | 0.00 | 0 | 7652 to 147 |
| 2026-10-09on bisoprolol | 103,299 | 0 | 0.00 | 0 | 7147 to 115 |
Counts are the Viatom device algorithm, not reviewed by a physician. All recordings were taken on bisoprolol, so they say nothing about the medicine. The large difference between May and October is a difference between recordings; the recordings alone do not say why. ST flags are not shown: they cover most of each recording and are a pattern, not events. Each recording in full: the 24-hour ECG page.
24 h blood pressure, 3 recordings
| Recording | Readings | 24 h mean | Day | Night | Night fall % |
|---|---|---|---|---|---|
| 2026-05-0513:03 to 05-06 09:30, on bisoprolol | 83 | 107/61 | 109/65n=47 | 104/57n=36 | 4.2 |
| 2026-05-1509:35 to 05-16 09:02, on bisoprolol | 911 flagged | 109/64all 92: 111/65 | 113/70n=55 | 104/56n=36 | 7.5 |
| 2026-10-0907:26 to 10-10 07:20, on bisoprolol | 631 flagged | 117/71all 64: 118/72 | 118/73n=46 | 114/66n=17 | 4.0 |
Means are systolic/diastolic in mmHg. Day and night follow the device clock. 3 of 3 24 h means are under the ESH 2023 threshold (130/80). The night fall is small in October; with only 3 recordings that is an observation, not a class. A recording is a run of readings with no gap over 12 h. Readings of 180 or more systolic or 120 or more diastolic are flagged as suspected mis-readings and left out of the means (rule chosen Oct 29); the mean with every reading stands beneath.
Home blood pressure
97 cuff readings on 22 days, 2026-04-15 to 2026-09-20: mean 111/70 mmHg. 4 readings with a diastolic of 95 or more or a pulse under 45 are flagged as suspected mis-readings and left out (rule chosen Oct 29); with them the mean is 112/72. The fullest week (Apr 16 to Apr 22, 53 readings) averaged 110/69. No home readings after Sep 20. Blood pressure page.
Breathing and oxygen
What the oximeter adds
35 nights with at least 4 h of finger-oximeter signal inside the ring's sleep window, Apr 28 to Nov 21, with no nights Jul 22 to Oct 07. 1 night with under 4 h of signal (Jul 23 3.9 h) is left out. Median per night: SpO2 94.3 %, ODI3 3.7/h, ODI4 1.9/h, time under 90 % 0.3 %. Mean SpO2 drifts down over the period (rank correlation with date r = -0.48, Spearman); the ring shows the same direction. The night ending Oct 11, the first after bisoprolol, stands out: nadir 82 %, 13 min under 90 %. Every night and the last night's curve: the night oximetry page.
Breathing rate in sleep: 13.9/min before treatment, 15.2 on bisoprolol, 14.0 since (ring).
Exploratory: nights with higher oximeter SpO2 also had higher ring HRV (rank correlation r = +0.63, Spearman, n=35 nights). One series, no adjustment for medicine or season; a lead to test, not a finding.
All oximeter nights
| Night ending | Hours | Mean SpO2 % | Lowest % | ODI3 /h | ODI4 /h | Under 90 % | Pulse |
|---|---|---|---|---|---|---|---|
| 2026-11-21off bisoprolol | 7.0 | 94.0 | 87 | 3.2 | 1.7 | 0.3 | 73 |
| 2026-11-14off bisoprolol | 6.5 | 93.8 | 84 | 5.1 | 3.1 | 0.8 | 81 |
| 2026-11-09off bisoprolol | 6.9 | 94.7 | 87 | 1.4 | 0.7 | 0.1 | 70 |
| 2026-11-06off bisoprolol | 7.2 | 93.8 | 87 | 7.8 | 4.3 | 1.5 | 75 |
| 2026-10-29off bisoprolol | 7.6 | 92.9 | 85 | 4.6 | 2.7 | 1.6 | 80 |
| 2026-10-28off bisoprolol | 7.1 | 94.0 | 86 | 3.2 | 2.3 | 0.3 | 70 |
| 2026-10-27off bisoprolol | 7.9 | 94.3 | 87 | 3.2 | 1.4 | 0.4 | 75 |
| 2026-10-25 *off bisoprolol | 6.3 | 94.2 | 86 | 2.5 | 1.7 | 0.3 | 78 |
| 2026-10-21off bisoprolol | 5.4 | 93.9 | 83 | 4.8 | 3.1 | 0.5 | 71 |
| 2026-10-19off bisoprolol | 9.0 | 96.0 | 90 | 1.7 | 0.9 | 0.0 | 68 |
| 2026-10-17off bisoprolol | 7.2 | 94.0 | 87 | 7.4 | 3.6 | 0.6 | 71 |
| 2026-10-13off bisoprolol | 8.3 | 94.1 | 88 | 3.0 | 1.3 | 0.3 | 68 |
| 2026-10-12off bisoprolol | 7.9 | 94.4 | 87 | 4.2 | 1.9 | 0.1 | 69 |
| 2026-10-11off bisoprolol | 8.2 | 93.9 | 82 | 10.0 | 7.3 | 2.6 | 75 |
| 2026-10-10on bisoprolol | 9.7 | 95.1 | 84 | 5.6 | 4.0 | 0.7 | 67 |
| 2026-10-09on bisoprolol | 7.2 | 94.4 | 84 | 3.5 | 1.8 | 0.3 | 64 |
| 2026-10-07on bisoprolol | 8.7 | 93.7 | 86 | 3.7 | 1.1 | 0.6 | 72 |
| 2026-07-22off bisoprolol | 6.2 | 93.9 | 86 | 5.5 | 3.2 | 0.3 | 73 |
| 2026-07-21off bisoprolol | 8.8 | 95.0 | 85 | 5.6 | 3.0 | 0.6 | 63 |
| 2026-07-09on bisoprolol | 7.2 | 95.7 | 89 | 3.0 | 1.2 | 0.1 | 63 |
| 2026-07-04on bisoprolol | 11.2 | 94.7 | 88 | 3.3 | 1.2 | 0.2 | 67 |
| 2026-06-26on bisoprolol | 7.8 | 94.0 | 87 | 4.4 | 1.9 | 0.2 | 66 |
| 2026-06-25on bisoprolol | 7.4 | 93.8 | 86 | 3.6 | 2.4 | 0.4 | 66 |
| 2026-06-24on bisoprolol | 10.0 | 93.8 | 84 | 6.9 | 3.9 | 0.9 | 63 |
| 2026-06-12on bisoprolol | 9.4 | 93.3 | 86 | 4.2 | 2.0 | 0.2 | 73 |
| 2026-06-11on bisoprolol | 9.8 | 94.3 | 84 | 2.6 | 1.3 | 0.4 | 76 |
| 2026-06-08on bisoprolol | 6.4 | 94.9 | 85 | 4.2 | 1.7 | 0.3 | 65 |
| 2026-06-07on bisoprolol | 8.5 | 94.7 | 87 | 4.4 | 2.2 | 0.4 | 66 |
| 2026-06-06on bisoprolol | 7.1 | 95.0 | 89 | 3.4 | 1.1 | 0.1 | 63 |
| 2026-05-16on bisoprolol | 7.8 | 94.9 | 88 | 6.2 | 4.0 | 0.2 | 65 |
| 2026-05-15on bisoprolol | 6.3 | 94.5 | 86 | 4.7 | 3.3 | 0.4 | 68 |
| 2026-05-06on bisoprolol | 7.5 | 95.6 | 92 | 1.2 | 0.7 | 0.0 | 60 |
| 2026-04-30on bisoprolol | 7.5 | 95.7 | 87 | 3.5 | 1.5 | 0.1 | 68 |
| 2026-04-29on bisoprolol | 11.2 | 95.6 | 86 | 3.1 | 1.5 | 0.2 | 62 |
| 2026-04-28on bisoprolol | 10.8 | 95.4 | 90 | 1.0 | 0.6 | 0.0 | 78 |
A desaturation is a drop of at least 3 points under the median of the previous 2 minutes that lasts at least 10 s before SpO2 is back within 1 point of that baseline; ODI4 counts the events that fell at least 4 points. Both are per hour of valid oximeter signal inside the ring's sleep window, so a night here can differ from an index computed over a whole recording. The 5/15/30 bands used for sleep apnoea are AHI bands, not ODI, and are not applied. * The oximeter recording of Oct 24 spanned the end of summer time at 03:00; its samples after the change are stamped one hour ahead and are shown as recorded. The later recordings were moved one hour back in the database on Oct 29.
Sleep
| Signal | Pre | Rux + BB | Off BB | Last 7 |
|---|---|---|---|---|
| Sleeph | 5.9n=64 | 6.9n=164 | 6.2n=43 | 6.7n=7 |
| Deep sleeph | 1.1n=64 | 1.3n=164 | 1.2n=43 | 1.1n=7 |
| REM sleeph | 0.9n=64 | 1.2n=164 | 1.1n=43 | 1.3n=7 |
| Sleep efficiency% | 79n=64 | 83n=164 | 82n=43 | 82n=7 |
Activity and temperature
| Signal | Pre | Rux + BB | Off BB | Last 7 |
|---|---|---|---|---|
| Steps per day | 1954n=67 | 2546n=167 | 2062n=44 | 2172n=6 |
| Temperature deviation°C | 0.06n=64 | 0.06n=164 | -0.02n=43 | 0.06n=7 |
Steps are the median per period; temperature is the ring's deviation from its own baseline.
Body
Flat within the noise
77 weigh-ins on 63 days, 2026-04-15 to 2026-11-22. The trend uses the 32 taken before 11:00 on 30 days; later weigh-ins are the open points. First four weeks 70.6 kg (n=10), July to November 70.6 kg (n=20). A single weigh-in scatters about ±0.6 kg, so nothing here is a change. Fat mass 14.8 kg (20.9 %) by bio-impedance, which is a consumer estimate, not a body-composition measurement. Last weigh-in: 2026-11-22, 72.1 kg.
Measurement quality
| Pair | Overlap | Mean difference | SD of differences | Correlation | Reading |
|---|---|---|---|---|---|
| Night pulse: oximeter vs ring | 35 nights | +0.16 bpm | 0.75 bpm | r = 0.99 | Two devices agree on the sleeping heart rate. |
| Night SpO2: oximeter vs ring | 27 nights | -1.07 pp | 0.78 pp | r = 0.62 | The finger oximeter reads about 1.1 point under the ring. Read each sensor against itself. |
| 24 h heart rate: ECG vs ring, 2026-05-04 | 190 ring samples | +1.9 bpm | ECG 70, ring 68.1 | ||
| 24 h heart rate: ECG vs ring, 2026-05-15 | 163 ring samples | +1.3 bpm | ECG 70, ring 68.7, oximeter 68.3 (15.5 h overlap) | ||
| 24 h heart rate: ECG vs ring, 2026-10-06 | 224 ring samples | +0.7 bpm | ECG 76, ring 75.3, oximeter 74.5 (19.9 h overlap) | ||
| 24 h heart rate: ECG vs ring, 2026-10-09 | 206 ring samples | +1.4 bpm | ECG 71, ring 69.6, oximeter 70.4 (21.6 h overlap) |
Same night or same 24 h window. Differences are device A minus device B. These are checks of the instruments, not findings about the body.
Coverage
| Source | Period | Amount | Last measurement | How it arrives |
|---|---|---|---|---|
| Oura ringsleep, HRV, heart rate, SpO2, temperature, breathing, steps | 2026-01-08 to 2026-11-24 | 310 nights | 2026-11-240 days before the last ring night | automatic, daily |
| Checkme O2 Maxnight SpO2 and pulse every 2 s | 2026-04-28 to 2026-11-21 | 35 nights of 4 h or more, 1 shorter left out | 2026-11-213 days before the last ring night | automatic, every 15 min |
| Viatom TH12 Holter24 h ECG, device algorithm | 2026-05-04 to 2026-10-09 | 4 recordings | 2026-10-0946 days before the last ring night | manual |
| Contec ABPM24 h blood pressure | 2026-05-05 to 2026-10-10 | 3 recordings | 2026-10-1045 days before the last ring night | manual |
| Omron M7 home BPmorning and evening cuff readings | 2026-04-15 to 2026-09-20 | 97 readings on 22 days | 2026-09-2065 days before the last ring night | automatic, hourly; no new readings since Sep 20 |
| Withings scaleweight, body composition | 2026-04-15 to 2026-11-22 | 77 weigh-ins on 63 days, 32 before 11:00 | 2026-11-222 days before the last ring night | automatic, hourly |
What this page cannot say
- No ECG recording off bisoprolol, so nothing about the medicine and the extra beats.
- No home blood pressure after sep 20, and no 24 h recording off bisoprolol.
- None of the device sources existed before treatment, so none of them enter the before/after analyses.
- No glucose and no symptom log in the database.
Go deeper
- Weekly Trackerthis week against last week, ring only
- Treatment Reportall systems, both medicines, for specialist review
- SpO2 & BOSring SpO2 trend and screening thresholds
- Blood pressurehome cuff and 24-hour recordings in detail
- Night oximetryevery finger-oximeter night, the last night as a curve
- 24-hour ECGeach Holter recording, the vendor's automatic analysis
- Piecewise ITSthe statistics behind the phase differences
- Sequential CIruxolitinib and bisoprolol effects in separate runs
- Placebo Testshow often random dates would show an effect
- Digital Twinthe model that projected the body without the medicines
- Every number, checkedwhich numbers on this site are audited