Blood pressure: home cuff and 24-hour monitor
The answer first
Coverage
97 clean readings on 22 days, 67 of them in April. 3 readings were dropped by the import as artefacts (impossible values or dates). No reading was taken before bisoprolol started on Apr 8 or after it stopped on Oct 10; 4 fell inside a pause.
| Month | Readings | Days | Morning | Afternoon | Evening | Irregular pulse | Mean sys/dia |
|---|---|---|---|---|---|---|---|
| April 2026 | 67 | 13 | 29 | 21 | 17 | 34 of 67 | 110/69 |
| May 2026 | 13 | 3 | 0 | 1 | 12 | 0 of 13 | 108/68 |
| June 2026 | 6 | 2 | 3 | 3 | 0 | 1 of 6 | 120/76 |
| July 2026 | 1 | 1 | 0 | 1 | 0 | 0 of 1 | 121/86 |
| August 2026 | 7 | 2 | 3 | 4 | 0 | 0 of 7 | 116/78 |
| September 2026 | 3 | 1 | 0 | 3 | 0 | 1 of 3 | 115/73 |
Morning, afternoon and evening are the cuff's own labels for the time of day.
Home readings over time
Every clean reading from the patient's slot, systolic and diastolic. The light band is the time on bisoprolol, the white gaps inside it are the pauses (May 20 to May 23 and Jul 20 to Aug 3), the dotted line is the stop. Rings mark readings where the cuff flagged an irregular pulse; grey open markers are the suspected mis-readings, which are left out of the averages. Dashed lines: the ESH 2023 home limit 135/85.
24-hour recordings
A 24-hour monitor inflates a cuff on the upper arm every 15 to 30 minutes, day and night. The patient wore a Contec PM50 three times: twice in May and once in October 2026, all while on bisoprolol. 'Asleep' is the ring's sleep window for that night; the device's own fixed clock (night 22 to 07) is shown underneath as a control.
| Recording | ReadingsESH asks 20 day, 7 night | 24 hlimit 130/80 | Awakelimit 135/85 | Asleeplimit 120/70, ring window | Night fall, systolicdipper 10 to 20 % | Pulseawake / asleep |
|---|---|---|---|---|---|---|
| A May 5 to May 613:03 to 09:30, 20 h | 8335 day, 20 night | 107/61 | 109/66n 52 | 102/54n 31, 00:13 to 07:47 | 7.1 %fixed clock 4.2 % | 67 / 62 |
| B May 15 to May 1609:35 to 09:02, 23 h | 9145 day, 20 night, 1 flagged | 109/64all 92 readings 111/65 | 113/69n 59 | 102/55n 32, 22:42 to 06:33 | 9.4 %fixed clock 7.5 % | 69 / 66 |
| C Oct 9 to Oct 1007:26 to 07:20, 24 h | 6336 day, 9 night, 1 flagged | 117/71all 64 readings 118/72 | 118/73n 43 | 116/67n 20, 20:56 to 06:45 | 1.9 %fixed clock 4.0 % | 74 / 71 |
Each panel is one recording; the shaded hours are the ring's sleep window. Dashed lines: the ESH 2023 limits for systolic pressure awake (135) and asleep (120). Grey open markers are the suspected mis-readings, which are left out of the averages. In the table, day readings are 09 to 21 and night readings 01 to 06 (ESH). 1 reading was dropped by the import as an artefact.
On May 5, 2026 the home cuff was used three times while the 24-hour monitor was running. Within 5 minutes of each other the cuff read on average -3.7 systolic and +3.7 diastolic against the monitor. Three pairs say nothing about device agreement in general; they are shown because they exist.
| Time | Home cuff | 24 h monitor | Minutes apart |
|---|---|---|---|
| May 05 13:04 | 108/68 | 105/63 | 1 |
| May 05 21:10 | 99/69 | 112/64 | 5 |
| May 05 21:11 | 111/65 | 112/64 | 3 |
- All three recordings were taken on bisoprolol. A recording without it is what is missing.
- The Contec PM50 is a consumer device. No comparison against a clinical reference device was made in this project.
- A cuff that inflates every 30 minutes can wake the wearer; the sleep readings are not undisturbed sleep.
- Frequent extra beats make oscillometric readings less precise. In recording A three readings between 02:15 and 02:45 show a pulse of 35 to 36 while the ring's nearest samples, within 60 minutes, read 63; they are kept, and they look like a pulse deficit rather than a true pulse.
- Two readings look physiologically odd (systolic 180 or more, or diastolic 120 or more: B, the last reading 234/180; C, 152/131 at 01:01). Since the rule was chosen on Oct 29, 2026 they are flagged as suspected mis-readings, left out of the averages in the table and shown as grey open markers in the panels. With them the 24 h means are B 111/65 and C 118/72. No other reading has been removed by hand.
Readings in series with the irregular-pulse flag
The cuff can take readings in a series of three about a minute apart and flags a reading when the pulse between inflations was irregular. 34 of 67 readings in April carried the flag (51 %); from the next month on, 2 of 30 did (36 of 97 in all). The flag is not a diagnosis; it also fires on frequent extra beats.
Context from the 24-hour ECGs: the vendor's automatic count found premature ventricular beats in 6.8 % and 11.4 % of beats in May and 0.004 % and 0 % in October, and no atrial fibrillation in any recording. See the 24-hour ECG page.
| Start | Readings | Sys/diamean of the series | Pulse | Irregular-pulse flags |
|---|---|---|---|---|
| Apr 15, 2026 10:47 | 2 | 106/74 | 76 | 0 of 2 |
| Apr 16, 2026 12:32 | 3 | 109/74 | 73 | 1 of 3 |
| Apr 16, 2026 14:17 | 5 | 117/75 | 79 | 1 of 5 |
| Apr 16, 2026 20:22 | 3 | 98/67 | 69 | 1 of 3 |
| Apr 16, 2026 20:45 | 3 | 98/58 | 63 | 2 of 3 |
| Apr 17, 2026 08:03 | 2 | 123/79 | 86 | 2 of 2 |
| Apr 18, 2026 08:45 | 3 | 113/73 | 63 | 2 of 3 |
| Apr 19, 2026 08:31 | 3 | 112/68 | 70 | 3 of 3 |
| Apr 19, 2026 20:33 | 2 | 96/64 | 66 | 1 of 2 |
| Apr 19, 2026 20:40 | 2 | 98/60 | 62 | 2 of 2 |
| Apr 20, 2026 08:42 | 6 | 117/70 | 72 | 5 of 6 |
| Apr 20, 2026 13:39 | 4 | 110/68 | 84 | 1 of 4 |
| Apr 20, 2026 15:51 | 3 | 110/67 | 71 | 0 of 3 |
| Apr 20, 2026 20:42 | 3 | 104/69 | 66 | 3 of 3 |
| Apr 21, 2026 19:39 | 3 | 108/57 | 65 | 3 of 3 |
| Apr 22, 2026 08:13 | 3 | 116/76 | 82 | 0 of 3 |
| Apr 24, 2026 07:30 | 3 | 117/72 | 74 | 2 of 3 |
| Apr 25, 2026 07:02 | 3 | 110/68 | 72 | 0 of 3 |
| Apr 28, 2026 12:16 | 3 | 105/66 | 78 | 1 of 3 |
| May 04, 2026 20:44 | 6 | 113/70 | 69 | 0 of 6 |
| May 05, 2026 21:09 | 3 | 104/67 | 62 | 0 of 3 |
| May 06, 2026 21:24 | 3 | 101/63 | 63 | 0 of 3 |
| Jun 04, 2026 14:41 | 3 | 116/75 | 71 | 1 of 3 |
| Jun 21, 2026 09:48 | 3 | 123/78 | 74 | 0 of 3 |
| Aug 03, 2026 13:13 | 4 | 113/77 | 80 | 0 of 4 |
| Aug 04, 2026 10:50 | 3 | 119/79 | 86 | 0 of 3 |
| Sep 20, 2026 12:24 | 3 | 115/73 | 72 | 1 of 3 |
27 series. Readings taken singly are in the chart above but not in this table.
Cuff pulse vs ring
70 cuff readings had a ring pulse sample within 10 minutes (ring times converted to Europe/Oslo). The cuff read -4.3 bpm against the ring (SD 8.5, 95 % limits of agreement -20.9 to +12.4, r 0.49). The cuff counts pulses at the arm during one inflation; the ring averages optical pulses over minutes. Extra beats can lower the cuff's count below the true rate.
Bland-Altman plot: each point is one reading, the solid line the mean difference, the dashed lines the 95 % limits of agreement.
Methods and limits
- Source: readings from user slot 1 of an Omron M7 Intelli IT, fetched from the device over Bluetooth. The device holds two users; the second slot is another person and is not on this page.
- Artefacts dropped at import: a pulse pressure under 20 mmHg, values outside the device range, and dates in the future (3 readings).
- ESH week: the first seven days with the cuff (Apr 15 to Apr 21), the first day discarded, morning and evening readings averaged (33 readings: 16 morning, 17 evening, on 6 days; afternoon readings are not part of the protocol). Pulse 69 bpm. The protocol asks for seven days with two readings morning and evening; this week meets the minimum of three such days, not the ideal.
- Morning and evening cards use every reading with that label. The earlier version of this page averaged sittings instead (readings closer than 10 minutes form a sitting, the first reading of each is discarded): overall 111/71 over 36 sittings, morning 113/72, evening 102/64.
- Repeatability: the median within-sitting SD of systolic pressure is 4.5 mmHg over 26 sittings with at least two readings. The average real variability across all consecutive readings, which the earlier page showed as a card, is 8.2 mmHg; it spans gaps of months and is not a property of one day.
- 24-hour recordings: readings closer than 12 h form one recording; a recording needs at least 20 readings. "Asleep" is the ring's sleep window; the device's fixed clock (22 to 07) is the control. 1 reading on May 1 is left out as too few for a recording.
- Four home readings look physiologically odd (a diastolic of 95 or more, or a pulse under 45): Apr 16 11:45 131/106, pulse 76; Apr 17 08:05 129/98, pulse 91; Apr 19 20:31 110/77, pulse 44; Apr 19 20:41 149/120, pulse 40. Since the rule was chosen on Oct 29, 2026 they are flagged as suspected mis-readings, left out of every average on this page and shown as grey open markers in the chart. With them the mean of all readings is 112/72 over 101 readings instead of 111/70 over 97, and the ESH week 110/69 over 36 readings instead of 108/67 over 33. No other reading has been removed by hand.
- No office blood pressure exists in this project, so white-coat or masked hypertension cannot be assessed.
- Limits: ESH 2023 home 135/85; ABPM 24 h 130/80, awake 135/85, asleep 120/70; a fall of 10 to 20 % in systolic pressure during sleep is the usual "dipper" range.
- One person, consumer devices, no physician review. Nothing here is a basis for clinical decisions.