Omron M7 cuff and Contec PM50 24 h monitor, not clinical measurementsN=1 case study, not validated for clinical decisionsHEV diagnosed Mar 18; Day 209 post-ruxolitinibMore
Consumer wearable data can support exploratory review only. The HEV diagnosis, temporally confounded with treatment start, remains a material confounder.

Blood pressure: home cuff and 24-hour monitor

Home readings from an Omron M7 cuff and three 24-hour recordings from a Contec PM50, against the ESH 2023 limits. One person; not a basis for clinical decisions.
ESH week
108/67mmHg
Apr 15 to Apr 21: 33 readings on 6 days, first day discarded. Home limit 135/85. With all 36 readings 110/69.
Morning
115/73mmHg
35 readings, Apr 15 to Aug 4
Evening
104/65mmHg
29 readings, Apr 16 to May 6
Irregular pulse flagged
34 of 67
readings in April; 2 of 30 from May on
Home cuff
97 readings, 22 days
Apr 15, 2026 to Sep 20, 2026; 4 flagged as suspected mis-readings
24-hour monitor
3 recordings, 237 readings
May 5, 2026 to Oct 10, 2026
Bisoprolol
Apr 8 to Oct 10
pauses May 20 to May 23 and Jul 20 to Aug 3
ANSWER

The answer first

The home readings in the ESH week (Apr 15 to Apr 21) averaged 108/67 mmHg, under the home limit of 135/85. The three 24-hour recordings averaged 107/61, 109/64, 117/71 mmHg (2 suspected mis-readings left out, see the limits below), all under the 24-hour limit of 130/80; the last one, in October, had almost no fall in pressure during sleep. The last home reading is from Sep 20, 2026; none has been taken or fetched since (65 days at the time of this build). Every reading on this page was taken between the start and the stop of bisoprolol; 4 home readings fell inside a pause.
COVERAGE

Coverage

97 clean readings on 22 days, 67 of them in April. 3 readings were dropped by the import as artefacts (impossible values or dates). No reading was taken before bisoprolol started on Apr 8 or after it stopped on Oct 10; 4 fell inside a pause.

MonthReadingsDaysMorningAfternoonEveningIrregular pulseMean sys/dia
April 2026671329211734 of 67110/69
May 202613301120 of 13108/68
June 2026623301 of 6120/76
July 2026110100 of 1121/86
August 2026723400 of 7116/78
September 2026310301 of 3115/73

Morning, afternoon and evening are the cuff's own labels for the time of day.

HOME READINGS

Home readings over time

Loading...

Every clean reading from the patient's slot, systolic and diastolic. The light band is the time on bisoprolol, the white gaps inside it are the pauses (May 20 to May 23 and Jul 20 to Aug 3), the dotted line is the stop. Rings mark readings where the cuff flagged an irregular pulse; grey open markers are the suspected mis-readings, which are left out of the averages. Dashed lines: the ESH 2023 home limit 135/85.

ABPM

24-hour recordings

A 24-hour monitor inflates a cuff on the upper arm every 15 to 30 minutes, day and night. The patient wore a Contec PM50 three times: twice in May and once in October 2026, all while on bisoprolol. 'Asleep' is the ring's sleep window for that night; the device's own fixed clock (night 22 to 07) is shown underneath as a control.

RecordingReadingsESH asks 20 day, 7 night24 hlimit 130/80Awakelimit 135/85Asleeplimit 120/70, ring windowNight fall, systolicdipper 10 to 20 %Pulseawake / asleep
A May 5 to May 613:03 to 09:30, 20 h8335 day, 20 night107/61109/66n 52102/54n 31, 00:13 to 07:477.1 %fixed clock 4.2 %67 / 62
B May 15 to May 1609:35 to 09:02, 23 h9145 day, 20 night, 1 flagged109/64all 92 readings 111/65113/69n 59102/55n 32, 22:42 to 06:339.4 %fixed clock 7.5 %69 / 66
C Oct 9 to Oct 1007:26 to 07:20, 24 h6336 day, 9 night, 1 flagged117/71all 64 readings 118/72118/73n 43116/67n 20, 20:56 to 06:451.9 %fixed clock 4.0 %74 / 71
Loading...

Each panel is one recording; the shaded hours are the ring's sleep window. Dashed lines: the ESH 2023 limits for systolic pressure awake (135) and asleep (120). Grey open markers are the suspected mis-readings, which are left out of the averages. In the table, day readings are 09 to 21 and night readings 01 to 06 (ESH). 1 reading was dropped by the import as an artefact.

Two devices, same minutes

On May 5, 2026 the home cuff was used three times while the 24-hour monitor was running. Within 5 minutes of each other the cuff read on average -3.7 systolic and +3.7 diastolic against the monitor. Three pairs say nothing about device agreement in general; they are shown because they exist.

TimeHome cuff24 h monitorMinutes apart
May 05 13:04108/68105/631
May 05 21:1099/69112/645
May 05 21:11111/65112/643
Limits of these recordings
  • All three recordings were taken on bisoprolol. A recording without it is what is missing.
  • The Contec PM50 is a consumer device. No comparison against a clinical reference device was made in this project.
  • A cuff that inflates every 30 minutes can wake the wearer; the sleep readings are not undisturbed sleep.
  • Frequent extra beats make oscillometric readings less precise. In recording A three readings between 02:15 and 02:45 show a pulse of 35 to 36 while the ring's nearest samples, within 60 minutes, read 63; they are kept, and they look like a pulse deficit rather than a true pulse.
  • Two readings look physiologically odd (systolic 180 or more, or diastolic 120 or more: B, the last reading 234/180; C, 152/131 at 01:01). Since the rule was chosen on Oct 29, 2026 they are flagged as suspected mis-readings, left out of the averages in the table and shown as grey open markers in the panels. With them the 24 h means are B 111/65 and C 118/72. No other reading has been removed by hand.
SERIES

Readings in series with the irregular-pulse flag

The cuff can take readings in a series of three about a minute apart and flags a reading when the pulse between inflations was irregular. 34 of 67 readings in April carried the flag (51 %); from the next month on, 2 of 30 did (36 of 97 in all). The flag is not a diagnosis; it also fires on frequent extra beats.

Context from the 24-hour ECGs: the vendor's automatic count found premature ventricular beats in 6.8 % and 11.4 % of beats in May and 0.004 % and 0 % in October, and no atrial fibrillation in any recording. See the 24-hour ECG page.

StartReadingsSys/diamean of the seriesPulseIrregular-pulse flags
Apr 15, 2026 10:472106/74760 of 2
Apr 16, 2026 12:323109/74731 of 3
Apr 16, 2026 14:175117/75791 of 5
Apr 16, 2026 20:22398/67691 of 3
Apr 16, 2026 20:45398/58632 of 3
Apr 17, 2026 08:032123/79862 of 2
Apr 18, 2026 08:453113/73632 of 3
Apr 19, 2026 08:313112/68703 of 3
Apr 19, 2026 20:33296/64661 of 2
Apr 19, 2026 20:40298/60622 of 2
Apr 20, 2026 08:426117/70725 of 6
Apr 20, 2026 13:394110/68841 of 4
Apr 20, 2026 15:513110/67710 of 3
Apr 20, 2026 20:423104/69663 of 3
Apr 21, 2026 19:393108/57653 of 3
Apr 22, 2026 08:133116/76820 of 3
Apr 24, 2026 07:303117/72742 of 3
Apr 25, 2026 07:023110/68720 of 3
Apr 28, 2026 12:163105/66781 of 3
May 04, 2026 20:446113/70690 of 6
May 05, 2026 21:093104/67620 of 3
May 06, 2026 21:243101/63630 of 3
Jun 04, 2026 14:413116/75711 of 3
Jun 21, 2026 09:483123/78740 of 3
Aug 03, 2026 13:134113/77800 of 4
Aug 04, 2026 10:503119/79860 of 3
Sep 20, 2026 12:243115/73721 of 3

27 series. Readings taken singly are in the chart above but not in this table.

CUFF VS RING

Cuff pulse vs ring

70 cuff readings had a ring pulse sample within 10 minutes (ring times converted to Europe/Oslo). The cuff read -4.3 bpm against the ring (SD 8.5, 95 % limits of agreement -20.9 to +12.4, r 0.49). The cuff counts pulses at the arm during one inflation; the ring averages optical pulses over minutes. Extra beats can lower the cuff's count below the true rate.

Loading...

Bland-Altman plot: each point is one reading, the solid line the mean difference, the dashed lines the 95 % limits of agreement.

METHODS

Methods and limits

  • Source: readings from user slot 1 of an Omron M7 Intelli IT, fetched from the device over Bluetooth. The device holds two users; the second slot is another person and is not on this page.
  • Artefacts dropped at import: a pulse pressure under 20 mmHg, values outside the device range, and dates in the future (3 readings).
  • ESH week: the first seven days with the cuff (Apr 15 to Apr 21), the first day discarded, morning and evening readings averaged (33 readings: 16 morning, 17 evening, on 6 days; afternoon readings are not part of the protocol). Pulse 69 bpm. The protocol asks for seven days with two readings morning and evening; this week meets the minimum of three such days, not the ideal.
  • Morning and evening cards use every reading with that label. The earlier version of this page averaged sittings instead (readings closer than 10 minutes form a sitting, the first reading of each is discarded): overall 111/71 over 36 sittings, morning 113/72, evening 102/64.
  • Repeatability: the median within-sitting SD of systolic pressure is 4.5 mmHg over 26 sittings with at least two readings. The average real variability across all consecutive readings, which the earlier page showed as a card, is 8.2 mmHg; it spans gaps of months and is not a property of one day.
  • 24-hour recordings: readings closer than 12 h form one recording; a recording needs at least 20 readings. "Asleep" is the ring's sleep window; the device's fixed clock (22 to 07) is the control. 1 reading on May 1 is left out as too few for a recording.
  • Four home readings look physiologically odd (a diastolic of 95 or more, or a pulse under 45): Apr 16 11:45 131/106, pulse 76; Apr 17 08:05 129/98, pulse 91; Apr 19 20:31 110/77, pulse 44; Apr 19 20:41 149/120, pulse 40. Since the rule was chosen on Oct 29, 2026 they are flagged as suspected mis-readings, left out of every average on this page and shown as grey open markers in the chart. With them the mean of all readings is 112/72 over 101 readings instead of 111/70 over 97, and the ESH week 110/69 over 36 readings instead of 108/67 over 33. No other reading has been removed by hand.
  • No office blood pressure exists in this project, so white-coat or masked hypertension cannot be assessed.
  • Limits: ESH 2023 home 135/85; ABPM 24 h 130/80, awake 135/85, asleep 120/70; a fall of 10 to 20 % in systolic pressure during sleep is the usual "dipper" range.
  • One person, consumer devices, no physician review. Nothing here is a basis for clinical decisions.