Viatom TH12 Holter, vendor's automatic analysis, not clinical measurementsN=1 case study, not validated for clinical decisionsHEV diagnosed Mar 18; Day 209 post-ruxolitinibMore
Consumer wearable data can support exploratory review only. The HEV diagnosis, temporally confounded with treatment start, remains a material confounder.

24-hour ECG (Holter)

Four 24-hour recordings with a Viatom TH12 in May and October 2026, all while on bisoprolol. The rhythm figures are the vendor's automatic analysis; no physician has reviewed them. One person.
Recordings
4
May 4, 2026 to Oct 9, 2026, 24 h each
PVC burden, May
6.8 and 11.4%
6,726 and 11,223 premature ventricular beats
PVC burden, October
0.004 and 0%
5 and 0 premature ventricular beats
Atrial fibrillation
0% of beats
vendor's automatic count, all four recordings
Device
Viatom TH12, 12 leads
the vendor's automatic analysis, no physician review
Medicine
all four on bisoprolol
Apr 8 to Oct 10; none after the stop
Beats analysed
411,557
over four days
WHO READ

Who read them

All rhythm figures on this page are the vendor's automatic analysis. No physician has reviewed the recordings. The vendor states in its report that the results are for reference only and not for diagnosis.

The May 4, 2026 recording is known from the vendor's PDF summary only; the other three also have the vendor's full analysis file. A recording was taken on each of four days, two in May and two in October 2026, all while the patient was on bisoprolol.

RECORDINGS

Each recording

RecordingHoursvalidBeatsHeart ratemean, min to maxPVCcount, %; couplets / bigeminy runsVT runsPAC / SVT runs
May 4 202608:35 to 08:35 next day; PDF summary only24valid n/a98,8747047 to 1046,7266.8 %; 1 / 811longest 2 s0 / 0
May 15 202609:22 to 09:22 next day24valid 23.798,1807048 to 12011,22311.4 %; 23 / 1663longest 4 s2 / 1longest SVT 2 s
Oct 6 202611:00 to 11:00 next day24valid 24.0111,2047652 to 14750.004 %; 0 / 009 / 0
Oct 9 202607:18 to 07:18 next day24valid 24.0103,2997147 to 11500 %; 0 / 000 / 0

Atrial fibrillation: 0 % of beats in all 4 recordings. Pauses flagged: none in the 3 recordings with a full analysis file; the May 4, 2026 summary does not list them. PVC: premature ventricular beat; PAC: premature atrial beat; VT and SVT: runs of three or more fast beats of ventricular or supraventricular origin, as the vendor's algorithm labels them. Counts are the algorithm's; no beat has been checked by hand. The vendor also flagged ST changes in each recording; they have not been reviewed by a physician and no count is shown.

PVC BURDEN

PVC burden

Loading...

The share of beats the algorithm labelled as premature ventricular was 6.8 % and 11.4 % in May and 0.004 % and 0 % in October. All four days were on bisoprolol, so the difference cannot be attributed to starting or stopping it; four days are not a trend, and PVC burden is known to vary a great deal from day to day.

For context, two thresholds appear in the literature: 10,000 or more PVC per 24 hours (EHRA/HRS/APHRS 2014) and 15 % or more of beats (AHA/ACC/HRS 2017), both as cited in a 2024 preprint on day-to-day variation (medRxiv 2024). The May 15, 2026 recording was above the first and below the second. The thresholds are quoted for orientation, not drawn as lines, because they belong in a physician's reading.

REFERENCE

ECG as reference for the wearables

A 24-hour ECG counts every beat, so its mean heart rate is the reference the wearables can be held against for the same hours. The ring samples optically every five minutes at rest and more often in motion; the finger oximeter every two seconds while worn; the 24-hour cuff once per inflation.

RecordingECG meanbpmRingmean of 5-min binsFinger oximetermean24 h cuffmeanRing lowestnight
May 470min 4768.1190 five-minute binsnot wornnot worn56
May 1570min 4868.7163 five-minute bins68.315.5 h67.992 readings55
Oct 676min 5275.3224 five-minute bins74.519.9 hnot worn63
Oct 971min 4769.6206 five-minute bins70.421.6 h73.463 readings58

Means over the hours each device was worn inside the ECG window, so they do not cover identical minutes. The lowest ring heart rate is for the night inside the recording.

HRV

Heart rate variability

RecordingECG SDNNms, 24 hECG RMSSDms, 24 hECG pNN50%Ring HRVms, night RMSSD
May 41146112.933
May 151126217.937
Oct 6105334.215
Oct 9103368.028

The ECG values are 24-hour figures from the vendor's algorithm and the ring's are night-time optical values, so the columns are not comparable. In May, thousands of premature beats inflate RMSSD and pNN50 (a premature beat and the pause after it count as large beat-to-beat changes), so differences between recordings in those columns are not shown as a change in autonomic tone.

LIMITS

What the numbers do not say

  • They are the output of one vendor's algorithm on one device; no physician has read the tracings.
  • The vendor flagged ST changes in each recording. They have not been reviewed by a physician and are not counted here.
  • Four days, months apart, are four observations, not a trend. The May and October recordings were taken under the same medicine, so they do not test the medicine.
  • No recording exists from before bisoprolol or after it was stopped.
  • Nothing here is a diagnosis or a basis for clinical decisions.